Reactor Cracking

Consumption figures

Based on a plant capacity of 1000 metric tons per year of R 12 as feed by an on-stream period of approx. 8,000 hours per year the expected consumption figures are as follows (as an example):

Raw materials
CCl2F21,000 kg
Oxygen350 - 390 kg/t R 12
Hydrogen35 -   40 kg/t R 12
 
Utilities
Dem Waterapprox. 272 kg/t R12
Cooling Waterapprox. 250 m3/t R12
Electric Power300 kWh/t R12
 
Byproducts and effluents
Waste gas
The waste gas composition is well within the requirements of the German Clean Air Regulations (TA-Luft).
Waste Water
Quantityapprox. 250 kg/h